India
08042782844

Please keep +91 or 0 before dialling the number.     Please keep +91 or 0 before dialling the number

+919426703391

Residual Current Circuit Breakers Manufacturers

RCCB (Residual Current Circuit Breaker by Shrinath Electric

Residual Current Circuit Breakers Manufacturers

Phone Number

08042782844

Please keep +91 or 0 before dialling the number.

Mon-Thu: 10 AM - 2 PM • Fri: 3 PM - 7AM

Other Website Visit our other website
Address 38, Umiya Estate, Shramjivi Vasahat, Rajendra park, Rakhial Rakhial, Nagarvel Hanuman Rd, Rakhial, Ahmedabad, Gujarat 380023

India, India, 380023

Description

Residual Current Circuit Breakers Manufacturers RCB distributed by Shrinath Electric provides RCCB with Residual Current Sensitivity – 10mA, 30mA, 100mA, 300mA, 500mA, 1000mA and Different Residual Current Sensitivity Tripping level serves a purpose. The recommended tripping level for max shock protection is 30mA which is provided by us as well. Note: A tripping level of 100 mA will still give a degree of shock protection if it’s unfeasible to use a 30mA device. While a 300mA should never be used for shock protection, its purpose is to supply fire and equipment protection. We also trade 2 Pole RCCB, which is employed just in case of a single-phase supply connection with only a live and a neutral wire. 3 Pole RCCB is analogous to a 4 Pole RCCB, but it only has three wires of a three-phase system. 4 Pole RCCB is used just in case of a three-phase supply connection also a further connection for the neutral of the availability. Providing topnotch after sales services is our topmost priority. Even though electricity has become a necessity in our lives, it comes with its own set of risks to human health and safety and property damage. Given the high risk of electrocution and fire from electricity, all electrical equipment must be adequately insulated. RCCB Panel Board Suppliers in GujaratRCCB Panel Board Dealers in Gujarat RCCB Panel Board Suppliers & Dealers in Ahmedabad, India A Residual Current Circuit Breaker (RCCB) is a critical safety safeguard when it comes to electrical circuit protection. If a problem develops in the connected circuit or if the current exceeds the rated sensitivity, the gadget acts as a current sensor device. It can measure and disconnect the connection automatically. As a result of Kirchhoff’s law, RCCB ensures a constant current flow in all circuits it inspects. RCCB compares the difference between the live and neutral wire current levels as a result. In an ideal world, the circuit’s live and neutral wires should have equal amounts of current. Reducing the neutral wire’s current when there is a problem is known as Residual Current. The RCCB trips off the circuit when it detects a Residual Current. The RCCB’s reliability is evaluated using a test circuit included with the Residual Current Device. A small number of current flows through the test circuit as soon as the test button is pressed. The RCCB tripped, and the supply was removed because it caused an imbalance on the neutral coil of the device. The circuit is automatically disconnected when the rated sensitivity is surpassed, protecting against earth faults and leakage currents. The RCCB also offers dual termination for cable and busbar connections. We, RCCB manufacturers, can help you to solve your problem. Features a filtering device to protect against transient voltage levels, which reduces the risk of voltage fluctuations.

Keywords

Other Products

view all

6814772a5d263414004dd4a4 Card 2

product image
Electric Panel

245 KVAR APFC PANEL A 245 KVAR APFC (Automatic Power Factor Correction) Panel is an electrical control panel used to improve power factor in industrial and commercial installations. It helps reduce power losses, avoids penalties from electricity boards, and increases the efficiency of the electrical system. Here are the key details about a 245 KVAR APFC Panel: 🔹 What it is APFC = Automatic Power Factor Correction. It automatically switches capacitor banks in and out based on the load requirement to maintain the desired power factor (typically above 0.95). The capacity here is 245 KVAR, meaning the panel can provide up to 245 kilo-volt-ampere reactive power compensation. 🔹 Technical Specifications (Typical) Capacity: 245 KVAR Voltage: 415V ±10% Frequency: 50 Hz Controller: Microprocessor-based APFC relay with multiple steps Capacitor Banks: Heavy-duty, low-loss, APP / MPP capacitors with detuned reactors (if required) Steps: Divided in multiple stages (e.g., 5 KVAR, 10 KVAR, 25 KVAR, 50 KVAR, etc. to reach 245 KVAR) Switching Device: Contactors / Thyristor-based switching (for fast response) Enclosure: MS powder-coated sheet metal, floor-mounted, IP42 / IP54 protection 🔹 Features Improves the power factor automatically. Reduces maximum demand charges. Minimizes penalty from utility providers. Enhances system efficiency by reducing reactive power. Protects against harmonics and resonance (if detuned reactors are used). Digital display for voltage, current, power factor, and step status. 🔹 Applications Large industries (steel, textile, cement, chemicals, etc.) Commercial complexes, malls, hospitals, hotels Any facility with heavy inductive loads like motors, compressors, HVAC systems Would you like me to create a detailed technical datasheet format (PDF/Word style) for a 245 KVAR APFC Panel that you can share with customers? You said: 1250 AMP MCC PANEL ChatGPT said: A 1250 Amp MCC (Motor Control Center) Panel is a centralized system for controlling multiple motors in industrial and commercial applications. It houses feeders, starters, protection devices, and monitoring systems, all integrated into one panel, designed to handle up to 1250 Amperes of current. Here’s a detailed breakdown: 🔹 What is an MCC Panel? An MCC Panel is used for controlling, protecting, and monitoring electric motors. It consists of motor starters, circuit breakers, fuses, contactors, overload relays, and metering devices. A 1250 Amp MCC Panel is designed for heavy-duty industries where multiple large motors are operated simultaneously. 🔹 Technical Specifications (Typical) Rated Current: 1250 Amps Rated Voltage: 415V ±10% (3 Phase, 50 Hz) Bus Bar Rating: Copper / Aluminum, 1250 Amps, insulated & color-coded Bus Bar Support: SMC / DMC, tested for temperature rise and short-circuit Fault Level: 50 kA / 65 kA / 100 kA (as per requirement) Ingress Protection: IP42 / IP54 / IP65 (as per site condition) Enclosure: CRCA sheet steel, powder-coated, floor-mounted Sections: Draw-out / Non-draw-out type feeders Cable Entry: Top / Bottom Control Voltage: 110V / 220V AC or 24V DC 🔹 Features Modular design for easy maintenance and expansion. Equipped with ACB (Air Circuit Breaker) or MCCB for incomer. Motor feeders with DOL / Star-Delta / VFD / Soft starter options. Overload, short-circuit, earth fault protection. Digital meters for voltage, current, power factor, frequency, kW, kVA, kVAR. SCADA / PLC / IoT compatibility for remote monitoring (optional). Energy-efficient design with copper busbars for minimal losses. 🔹 Applications Heavy industries: Cement, Steel, Chemicals, Pharmaceuticals, Paper, Food Processing. Utilities: Water treatment plants, Sewage plants, HVAC systems. Large commercial complexes, data centers, hospitals, airports.

6814772a5d263414004dd4a4 Card 2

product image
Electric Panel

245 KVAR APFC PANEL Manufacturers A 245 KVAR APFC (Automatic Power Factor Correction) Panel is an electrical control panel used to improve power factor in industrial and commercial installations. It helps reduce power losses, avoids penalties from electricity boards, and increases the efficiency of the electrical system. Here are the key details about a 245 KVAR APFC Panel: 🔹 What it is APFC = Automatic Power Factor Correction. It automatically switches capacitor banks in and out based on the load requirement to maintain the desired power factor (typically above 0.95). The capacity here is 245 KVAR, meaning the panel can provide up to 245 kilo-volt-ampere reactive power compensation. 🔹 Technical Specifications (Typical) Capacity: 245 KVAR Voltage: 415V ±10% Frequency: 50 Hz Controller: Microprocessor-based APFC relay with multiple steps Capacitor Banks: Heavy-duty, low-loss, APP / MPP capacitors with detuned reactors (if required) Steps: Divided in multiple stages (e.g., 5 KVAR, 10 KVAR, 25 KVAR, 50 KVAR, etc. to reach 245 KVAR) Switching Device: Contactors / Thyristor-based switching (for fast response) Enclosure: MS powder-coated sheet metal, floor-mounted, IP42 / IP54 protection 🔹 Features Improves power factor automatically. Reduces maximum demand charges. Minimizes penalty from utility providers. Enhances system efficiency by reducing reactive power. Protects against harmonics and resonance (if detuned reactors are used). Digital display for voltage, current, power factor, and step status. 🔹 Applications Large industries (steel, textile, cement, chemicals, etc.) Commercial complexes, malls, hospitals, hotels Any facility with heavy inductive loads like motors, compressors, HVAC systems Would you like me to create a detailed technical datasheet format (PDF/Word style) for a 245 KVAR APFC Panel that you can share with customers? You said: 1250 AMP MCC PANEL ChatGPT said: A 1250 Amp MCC (Motor Control Center) Panel is a centralized system for controlling multiple motors in industrial and commercial applications. It houses feeders, starters, protection devices, and monitoring systems, all integrated into one panel, designed to handle up to 1250 Amperes of current. Here’s a detailed breakdown: 🔹 What is an MCC Panel? An MCC Panel is used for controlling, protecting, and monitoring electric motors. It consists of motor starters, circuit breakers, fuses, contactors, overload relays, and metering devices. A 1250 Amp MCC Panel is designed for heavy-duty industries where multiple large motors are operated simultaneously. 🔹 Technical Specifications (Typical) Rated Current: 1250 Amps Rated Voltage: 415V ±10% (3 Phase, 50 Hz) Bus Bar Rating: Copper / Aluminum, 1250 Amps, insulated & color-coded Bus Bar Support: SMC / DMC, tested for temperature rise and short-circuit Fault Level: 50 kA / 65 kA / 100 kA (as per requirement) Ingress Protection: IP42 / IP54 / IP65 (as per site condition) Enclosure: CRCA sheet steel, powder-coated, floor-mounted Sections: Draw-out / Non-draw-out type feeders Cable Entry: Top / Bottom Control Voltage: 110V / 220V AC or 24V DC 🔹 Features Modular design for easy maintenance and expansion. Equipped with ACB (Air Circuit Breaker) or MCCB for incomer. Motor feeders with DOL / Star-Delta / VFD / Soft starter options. Overload, short-circuit, earth fault protection. Digital meters for voltage, current, power factor, frequency, kW, kVA, kVAR. SCADA / PLC / IoT compatibility for remote monitoring (optional). Energy-efficient design with copper busbars for minimal losses. 🔹 Applications Heavy industries: Cement, Steel, Chemicals, Pharmaceuticals, Paper, Food Processing. Utilities: Water treatment plants, Sewage plants, HVAC systems. Large commercial complexes, data centers, hospitals, airports. 👉 Would you like me to prepare a professional datasheet / catalog-style content (PDF/Word) for the 1250 Amp MCC Panel, similar to an OEM product brochure, that you can directly share with clients? ChatGPT can make mistakes. Check important info. See Cookie Preferences.

6814772a5d263414004dd4a4 Card 2

product image
ACB Distribution Panel

ACB Distribution Panel Manufacturer We also supply in Ahmedabad, Amreli, Banaskantha, Bharuch, Bhavnagar, Dang, Jamnagar, Junagadh, Kheda, Kachchh, Mehsana, Panchmahal, Rajkot, Sabarkantha, Surat, Surendranagar and Vadodara. Shrinath Electric” are a Sole Proprietorship based firm, engaged as the foremost Manufacturer And Retailer of ACB Distribution Panel ,PLC Panel, MCC Panel, APFC Panel and many more.